[ABB] (auto black balance)
Adjust the auto black balance in following cases.
When the camera is used for the first time
When it has past extensive time after used previously
When the ambient temperature has changed extensively after used previously
Operating Instructions AU-EVA1
Adjust the auto black balance in following cases.
When the camera is used for the first time
When it has past extensive time after used previously
When the ambient temperature has changed extensively after used previously
Mount the cap on the lens.
Make sure the light does not get to the image sensor.
Select the [CAMERA SETTINGS] menu → [AUTO BLACK BALANCE] → [ABB] → [EXECUTE].
Do not remove the lens cap or set the power to <
> (standby) while [ABB ACTIVE] is displayed on the LCD monitor.
Select the [SCENE FILE SETTINGS] menu → [BLACK] → [M.PED]/[R PED]/[G PED]/[B PED].
[M.PED] (master pedestal): Adjusts the reference black level of the whole video. The adjusted value is maintained even when the auto black balance is executed.
[R PED] (red signal pedestal), [G PED] (green signal pedestal), [B PED] (blue signal pedestal): Adjusts the reference black level for each signal. Depending on the setting in the [SCENE FILE SETTINGS] menu → [BLACK] → [PEDESTAL OFFSET], it can be set if the adjusted value is to be maintained or not when the auto black balance is executed.