| General | ||
|---|---|---|
| Power Requirements | 12 V DC, DC 42 V to 57 V (PoE++ power supply) | |
| Current Consumption | 3A (Connector Input), 1A (PoE++ power supply) | |
| Ambient Operating Temperature | 0 ℃ to 40 ℃ (32 °F to 104 °F) | |
| Storage Temperature | -20 ℃ to 50 ℃ (-4 °F to 122 °F) | |
| Allowable Humidity | 20 % to 90 % (no condensation) | |
| Mass | Approx. 3.5 kg (7.72 lb) | |
| Dimensions (W x H x D) | 364 mm x 178 mm x 245 mm (14-11/32 inches x 7 inches x 9-21/32 inches) (excluding protrusions) |
|
| Input/Output Connectors | ||
| Input | DC 12 V IN | XLR 4‑pin |
| 3G SDI IN | SMPTE424M*1/SMPTE292M / 75 Ω (BNC x 1) Supported formats: 1080/59.94p*1, 1080/50p*1, 1080/29.97p, 1080/25p, 1080/23.98p, 1080/59.94i, 1080/50i |
|
| Output*2 | 3G SDI OUT | SMPTE424M*3/SMPTE292M / 75 Ω (BNC x 1) |
| Input/Output | LAN | IP Control LAN Port (RJ-45) Connection cable: LAN cable, max. 100 m (328 ft) • When connecting the unit via a switching hub: Straight cable or a cross cable (category 5e cable), STP (Shielded Twisted Pair) cable recommended • When connecting the unit directly: Crossover cable (category 5e cable), STP (Shielded Twisted Pair) cable recommended |
| RS-422 (1-3) | Serial Control Port (RJ-45) RS‑422 (control signals for remote cameras), TALLY OUT Connecting cable: Straight cable (category 5e or better shielded cable), max. 1000 m (3280 ft) TALLY OUT: Open collector output (negative logic), Maximum voltage resistance DC 24 V, Maximum current 50 mA |
|
| GPIO | D‑sub 25‑pin x2, female, inch thread MODE 1 GPIO 1: TALLY IN: 20 inputs (R-TALLY and G-TALLY, 10 pins each), GPI OUT: Alarm GPIO 2: GPI IN (CAM SEL 1-10), GPI OUT (CAM SEL 1-10) MODE 2 GPIO 1: TALLY IN: 10 inputs (R-TALLY 10pin), GPI IN (PMEM Group 1-4, Menu ENABLE_BUTTON), GPI OUT (GROUP SEL 1-5, Alarm) GPIO 2: GPI IN (PRESET SEL1-10, CAM SEL 1-10) MODE 3 GPIO 1: TALLY IN: 10 inputs (R-TALLY 10pin), GPI IN (CAM GROUP SEL 1-5), GPI OUT (CAM GROUP SEL 1-5, Alarm) GPIO 2: GPI IN (CAM SEL BUTTON 1-10), GPI OUT (CAM SEL BUTTON 1-10) * When TALLY IN: Contact input (status operation) * When GPI IN: Contact input (trigger operation) * When GPI OUT: Open-collector output (negative logic), Maximum withstand voltage DC 24 V, Maximum current 50 mA |
|
| USB | USB 2.0 (5 V 0.5 A Type A x1, Type C x1) | |
| Input/Output | ||
| LCD Display | 7-inch Touch Panel GUI Monitor (WVGA (800x480)) | |
| Connection Specifications | ||
| No. of Connectable Cameras | 200 (IP), 3 (RS-422) | |
| No. of Camera Selection Buttons | 20 | |
| Memory | ||
| Preset Memory | No. of memory presets 100 per camera | |
| Tracing Memory | Maximum total duration: 5 minutes per camera; Maximum of 10 settings per camera (CAM1 to CAM10) |
|
| Macro Memory | No. of macros 100 | |
| Other Functions | ||
| Tally LED Display Color | green / red / yellow | |
- *1: Automatic Level-A/B Detection.
- *2: Output when the unit is powered on.
- *3: Level-A support only.
- * AC adapter not included. Requires separate 12 V XLR 4-pin power supply for power consumption.