- Top
- Menu Operations
- Menu list
- [SYSTEM MODE]
[FORMAT] cannot be selected right after the power is turned on, because boot of the camera is in progress.
This is not an error. Perform operation after a while.
Item |
Description of settings |
|
[FORMAT] |
Sets the system format. [2160/59.94p], [2160/29.97p], [2160/23.98p], [1080/59.94p-120fps], [1080/59.94p], [1080/29.97p], [1080/23.98p], [2160/50p], [2160/25p], [1080/50p-100fps], [1080/50p], [1080/25p]
|
|
[COLOR SETTING] |
Sets the colors of entire camera system. [NORMAL]: Enables fine image quality adjustments from the camera as with previous studio cameras. [V-LOG]: Uses a gamma curve which can achieve a wide range of tone and exposure. Color grading will be necessary after shooting.
|
|
NOTE
|
||
[V-LOG PAINT SW] |
Selects whether to make it possible to make settings in the [PAINT] menu when [COLOR SETTING] is [V-LOG]. [OFF], [ON]
|
|
NOTE
|
||
[COLORIMETRY] |
Change the Y/C conversion coefficient. [BT.709], [BT.2020]
|
|
NOTE
|
||
[GAMUT] |
Change the color gamut. [NORMAL], [WIDE_G], [WIDE_G2]
|
|
NOTE
|
||
[HDR SW] |
— |
Enables/disables the HDR mode. [OFF], [ON]
|
[HD_SDI1 OUT(HDR)] |
Enables/disables the HDR signal from the <HD SDI1> terminal. [OFF], [ON]
|
|
[HD_SDI2 OUT(HDR)] |
Enables/disables the HDR signal from the <HD SDI2> terminal. [OFF], [ON]
|
|
[SHOOTING MODE] |
Sets the shooting mode. [NORMAL], [HIGH SENS]
|
|
[SCAN MODE] |
Selects the scan mode of the sensor. [NORMAL], [LOW SKEW]
|
|
[CABLE CONNECTION] |
Set the connection method used between the camera and CCU. [HYBRID], [FIBER]
|