[BATTERY SETUP]

Configure the settings for the battery to use.

Item

Description of settings

[BATTERY SELECT]

Selects the battery to use.

[HYTRON140], [DIONIC HC], [ENDURA10], [PAG L96e]: Detects the battery charge level according to the selected battery when the HYTRON140, DIONIC HC by Anton/Bauer, ENDURA10 (E-10) by IDX, or PAG L96e by PAG battery is selected.

[TYPE A], [TYPE B], [TYPE C]: Select either item when a battery other than [HYTRON140], [DIONIC HC], [ENDURA10], and [PAG L96e] is used. At this time, set [FULL] (full voltage), [NEAR END] (near end warning voltage), or [END] (end voltage) in the main menu → [BATTERY SETUP] → [BATTERY SETTING] ([BATTERY SETTING]) according to the battery in use.

[BATT STAT]: By selecting [BATT STAT] when using a battery whose charge level is detected as a percentage value, near end and end operations are conducted according to the percentage value of the charge level. Set the percentage value of [BATT STAT NEAR END] (near end) and [BATT STAT END] (end) in the main menu → [BATTERY SETUP] → [BATTERY SETTING] ([BATTERY SETTING]) according to the battery in use.

[ENDURA STAT]: Select it when ENDURA battery by IDX is used to perform near end and end operations according to the percentage value of the charge level information. Set the percentage value of [ENDURA STAT NEAR END] (near end) and [ENDURA STAT END] (end) in the main menu → [BATTERY SETUP] → [BATTERY SETTING] ([BATTERY SETTING]) according to the battery in use.

  • Factory setting: [DIONIC HC]

When the battery charge level percentage cannot be detected even if [BATT STAT] or [ENDURA STAT] is set, it will follow the setting value of [TYPE A]. Make sure that the [TYPE A] setting values for [FULL] (fully charged), [NEAR END] (near end), and [END] (end) are appropriate for the battery in use.

[EXT DC IN SELECT]

Sets the type of charge level detection when a battery is connected to the <DC IN> terminal. Also detects a charge level that corresponds to the selected type.

Selection of a battery type is the same as that of [BATTERY SELECT].

Displays the analog voltage in the viewfinder.

[DC PWR SUPPLY], [HYTRON140], [DIONIC HC], [ENDURA10], [PAG L96e], [TYPE A], [TYPE B], [TYPE C]

  • Factory setting: [DC PWR SUPPLY]

[BATT NEAR END CANCEL]

If set to [ON], the warning sound and warning display output can be canceled when the <DISP/MODE CHK> switch is pushed towards the <CHK> side at battery near end.

[ON], [OFF]

  • Factory setting: [ON]

[BATT REMAIN FULL]

Sets the content of the battery remaining charge bar of SmartUI when a battery with charge level display function is used.

[70%]: Displays as full at 70%.

[100%]: Displays as full at 100%.

  • Factory setting: [70%]

[BATTERY SETTING]

[BATTERY MODE]

Selects whether to set the near end voltage of a battery.

[AUTO]: Automatically set.

[MANUAL]: Manually set.

  • Factory setting: [AUTO]

[HYTRON140 NEAR END]

Selects the near end voltage in steps of 0.1 V when [HYTRON140] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

This item is enabled when [BATTERY MODE] is set to [MANUAL].

[12.0V]…[15.0V]

  • Factory setting: [13.1V]

[DIONIC HC NEAR END]

Selects the near end voltage in steps of 0.1 V when [DIONIC HC] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

This item is enabled when [BATTERY MODE] is set to [MANUAL].

[12.0V]…[15.0V]

  • Factory setting: [13.4V]

[ENDURA10 NEAR END]

Selects the near end voltage in steps of 0.1 V when [ENDURA10] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

This item is enabled when [BATTERY MODE] is set to [MANUAL].

[12.0V]…[15.0V]

  • Factory setting: [13.4V]

[PAG L96e NEAR END]

Selects the near end voltage in steps of 0.1 V when [PAG L96e] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

This item is enabled when [BATTERY MODE] is set to [MANUAL].

[12.0V]…[15.0V]

  • Factory setting: [12.7V]

[TYPE A FULL]

Selects the voltage for full display in steps of 0.1 V when [TYPE A] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.

[13.0V]…[17.0V]

  • Factory setting: [15.6V]

[TYPE A NEAR END]

Selects the near end voltage in steps of 0.1 V when [TYPE A] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.

[11.0V]…[15.0V]

  • Factory setting: [13.2V]

[TYPE A END]

Selects the end voltage in steps of 0.1 V when [TYPE A] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.

[11.0V]…[15.0V]

  • Factory setting: [12.5V]

[TYPE B FULL]

Selects the voltage for full display in steps of 0.1 V when [TYPE B] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.

[13.0V]…[17.0V]

  • Factory setting: [15.9V]

[TYPE B NEAR END]

Selects the near end voltage in steps of 0.1 V when [TYPE B] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.

[11.0V]…[15.0V]

  • Factory setting: [12.9V]

[TYPE B END]

Selects the end voltage in steps of 0.1 V when [TYPE B] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

The [TYPE B] factory setting corresponds to the Anton/Bauer DIONIC HC.

[11.0V]…[15.0V]

  • Factory setting: [12.5V]

[TYPE C FULL]

Selects the voltage for full display in steps of 0.1 V when [TYPE C] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

[13.0V]…[17.0V]

  • Factory setting: [15.9V]

[TYPE C NEAR END]

Selects the near end voltage in steps of 0.1 V when [TYPE C] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

[11.0V]…[15.0V]

  • Factory setting: [13.2V]

[TYPE C END]

Selects the end voltage in steps of 0.1 V when [TYPE C] is selected in the main menu → [BATTERY SETUP] → [BATTERY SELECT].

[11.0V]…[15.0V]

  • Factory setting: [12.5V]

[BATT STAT NEAR END]

Selects the near end percent value.

When the battery charge level percentage cannot be detected, this will follow the near end voltage value set for [TYPE A].

[4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]

  • Factory setting: [5%]

If a battery whose remaining charge is displayed in units of 10% is used, the setting value and actual near end warning may vary slightly.

[BATT STAT END]

Selects the end percent value.

When the battery charge level percentage cannot be detected, this will follow the end voltage value set for [TYPE A].

[1%]…[10%]

  • Factory setting: [1%]

When using a battery which displays battery charge level by units of 10%, an end is determined only in two stages: when it is set between [1%] and [5%], or when it is set between [6%] and [10%].

[ENDURA STAT NEAR END]

Selects the near end percent value.

When the battery charge level percentage cannot be detected, this will follow the near end voltage value set for [TYPE A].

[4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]

  • Factory setting: [5%]

If a battery whose remaining charge is displayed in units of 10% is used, the setting value and actual near end warning may vary slightly.

[ENDURA STAT END]

Selects the end percent value.

When the battery charge level percentage cannot be detected, this will follow the end voltage value set for [TYPE A].

[1%]…[10%]

  • Factory setting: [1%]

When using a battery which displays battery charge level by units of 10%, an end is determined only in two stages: when it is set between [1%] and [5%], or when it is set between [6%] and [10%].