Operation displays

The operation displays appear at the bottom of the screen for approx. 4 seconds when any of the following operations have been performed with the operation panel of the ROP.

  • Master gain change
  • Electronic shutter change
  • Lens extender change
  • Scene file change
  • REF LOAD is changed
  • FILTER is changed

The display time can be changed from [MAINTENANCE] menu > [PM OPERATION STATUS] > [STATUS DISP TIME].

53561.png

Item

Display range

Remarks

MASTER GAIN

Setting values on camera

The master gain value is displayed here.

  • For the setting values, refer to the Operating Instructions for the camera.

SHUTTER

Setting values on camera

The speed of the electronic shutter is displayed here.

  • For the setting values, refer to the Operating Instructions for the camera.

LENS EXT

1.0

2.0

The magnification of the lens extender is displayed here.

  • When the magnification of the lens extender is set to 2x, [2.0] is displayed. Otherwise, [1.0] is displayed.

SCENE FILE

OFF

1 to 8

This indicates the scene file name.

REF LOAD

FACTORY

USER1 to USER3

REF1 to 3

This indicates the reference file that was loaded via reference call recalling.

FILTER

****

(ND/CC filter name)