• Top
  • Specifications

Specifications

Power supply

AK-UCU600P/AK-UCU600PS : 100 V - 120 V AC (52713.png), 50 Hz/60 Hz

AK-UCU600E/AK-UCU600ES : 100 V - 240 V AC (52722.png), 50 Hz/60 Hz

Power consumption

500 W

(Without camera connected: 90 W)

Capacity for supplying power to a camera

240 V AC (52840.png), 1.46 A , 50 Hz/60 Hz

53069.jpg indicates safety information.

Operating temperature

0 °C to 40 °C (32 °F to 104 °F)

Humidity

10% to 90% (no condensation)

Dimensions

(Width×Height×Depth)

424 mm × 88 mm × 401 mm (16-5/8 inches × 3-7/16 inches × 15-13/16 inches) (excluding protrusions)

Weight

Approx. 8.9 kg (19.6 lb)

Video output

3G/HD-SDI

5 lines (embedded audio is supported only for HD signals)

12G/6G/3G/HD-SDI

2 lines

HD-SDI

1 line (shared with picture monitor output*2)

Analog composite

2 lines (1 line shared with picture monitor output*2)

HD TRUNK/TICO output

When HD TRUNK: HD-SDI, when TICO: 3G/HD-SDI

1 line

Return input

3G-HD/HD/SD-SDI

4 lines (RET1 input has active-through output)

Analog composite

1 line

Prompter input

HD-SDI

1 line (with active-through output)

Analog composite

2 lines (through output of 1 and input of 2 share the connector*2)

It is not terminated when the unit is turned OFF. No through output.

Reference input

BB (black burst) / tri-level*1

1 line (automatic termination, connect to upper connector; BB signal and tri-level signal automatically recognized, with loop-through output)

Microphone output

0 dBm/600 Ω

2 lines (XLR, 3-pin, male)

Communication

Intercom input/output

(ENG / PROD, 0 dBm, 600 Ω (4 W) / 1 V [p-p], 200 Ω (RTS), 4 W / RTS / CLRCOM)

2 lines*2

PGM input (0 dBm/600 Ω)

2 lines

Tally input (red, green, yellow)

1 input each

AUX

WFM control

6-bit (open collector output, terminal shared with camera microphone gain setting*2)

Camera microphone gain setting input

5-bit (photo-coupler input, terminal shared with WFM control*2)

Down-conversion system setting input

2-bit (photo-coupler input)

TRUNK

RS-422 / RS-232C

2 lines*2

FRONT ROP

RS-422

1 line, 16 V DC output (only one of this and REAR ROP can be selected at one time via the menu or the [ROP FRONT/REAR] selection switch on the front panel)

REAR ROP

RS-422

1 line, 16 V DC output (only one of this and FRONT ROP can be selected at one time via the menu or the [ROP FRONT/REAR] selection switch on the front panel)

MSU

RS-422

1 line, GPI for control

LAN TRUNK

LAN connection with camera side via an optical cable*3

1 line, 100BASE-TX, 1000BASE-T

LAN

Personal computer connection for distribution via the Web*3

1 line, 10BASE-T, 100BASE-TX (use a crossover cable when connecting directly with a personal computer)

The BB (black burst) signal and tri-level sync signal of the reference input are recognized automatically.

Depending on the setting, only one of them can be selected at one time.

IP video is cannot be transmitted when [CCU MODE] is set to [2160/23.98p], [2160/23.98psf], [1080/23.98p], or [1080/23.98psF].

The symbols on this product (including the accessories) represent the following:

53039.png AC

53030.png Power on

53022.png Power off

Inrush current, measured according to European standard EN55103-1, on initial switch-on: 3 A, after a supply interruption of 5 s: 80 A