Set [DF] or [NDF] in the main menu → [RECORDING SETUP] → [DF MODE].
Set [DF] to advance the time code in the drop frame mode, and set [NDF] to advance it in the non-drop frame mode. However, note that the time code runs by [NDF] at all times in the 24PN mode.
Press the <SETUP> button to display the [SET01:TC/UB] screen of SmartUI.
Press the <COUNTER> button to set the counter display to [UB].
Press the </REW> button to set [TCG] to [SET].
Set the time code.
Press the upper or lower buttons that correspond to the following screen displays.
[→]: The digit to be set (flashing) moves to the right.
[+]: The digit to be set (flashing) moves to the left.
[−]: The value of the digit to be set (flashing) is incremented by one.
[RST]: The value of the digit to be set (flashing) is decremented by one.
Press the </REW> button, enter the setting values of the time code, and exit the time code settings screen.
Press the <HOME> button to display the [HOME] screen of SmartUI.
Settable time code range
Video signal
Setting range
For 59.94 Hz (except for 24PN)
00:00:00:00 to 23:59:59:29
24PN
00:00:00:00 to 23:59:59:23
For 50 Hz
00:00:00:00 to 23:59:59:24
Time code function during battery replacement
Even during battery replacement, the backup mechanism functions, allowing the time code generator to continue operating.
When each item of the system mode has been changed, the time code of free run may shift. Turn on the power again, check the time code, and reset it, if necessary.